Hi Martin,

 

BWD 500 has which system role in your test project? I can only see in the maintenance cycle screen that your dev is BWD 200.

 

Please send me the screenshot of tables /TMWFLOW/TTRCKHC and /TMWFLOW/TTRCKEC. Your transport tracks seem to be inconsistent. It seems that a target system (such as QAS) is set as single system but has a previous system in table /TMWFLOW/TTRCKEC, which causes the error you have (has a predecessor).

 

 

If BWD 500 is a QAS system and it's not configured as "Target Systems" in the system role assignment (for instance, if it's set as Single System), your project will be locked by ChaRM consistency check.


If this is the case, in order to unlock your project, do the following:

 

- Go to SOLAR_PROJECT_ADMIN, tab System Landscape->Systems

- Scroll down and click the pencil in "System Role Assignment"

- Select "Edit System Roles"

- Check if the QAS systems have Type of Role as Target Systems. If not, change it. Save.

See picture below:

 

img1.jpg

- Now Refresh again the project in the Change Management->Change Request Mgt area. And repeat the check.

 

Let me know the results.

 

Regards,

Raquel